Pressure testing

 
42 
4.  Assemble upper bracket to lower bracket 
so  that  the  underside  of  bracket  is 
dimension  'C' +  3mm  above  floor  level.  
(See Fig. 3b) 
Reposition appliance and check that top 
bracket engages into appliance back as 
shown in Fig. 3b. 
Pressure testing 
1.  The oven injector is used as a pressure 
test point. 
Remove  the  oven  furniture.    Remove 
oven  burner  box  retaining  clips  (one 
spring clip from each side) and remove 
box front cover.  Replace one clip back 
into  the  right  hand  side  of  the  burner 
box.   
Remove  oven  burner  by  removing  the 
spring  clip  from  the  right  hand  side  of 
the  oven  burner  and  slide  burner
  off 
injector,  whilst  easing  it  forward  and 
taking  care  not  to  strain  the  F.S.D. 
phial. 
2.  Connect  the  pressure  gauge  to  the 
oven injector.  
3.  Check  the  supply  pressure  by  turning 
the thermostat on and one hotplate tap 
full on and light the appropriate burner. 
  The pressure should be either:- 
(i) 
For Natural Gas 20mbar  
(ii) 
For LP. Gas. The pressure must 
be  set  to  28  mbar  for  use  on 
butane  or  37  mbar  for  use  on 
propane. 
4.  Turn  off  the  taps,  disconnect  the 
pressure gauge and replace oven burner 
and cover, ensuring that the F.S.D phial 
is  correctly  located  into  the  bracket  on 
the burner.  
5.  Check operation of the oven. 
 
 
 
 
 
Checking the grill 
Place  the  grill  pan  containing  the  grid,  with 
the  handle  attached,  into  the  grill 
compartment.    Light  the  grill  burner  by 
turning the grill tap full on and pressing the 
ignition button on the fascia panel.  As soon 
as  the  burner  is  lit  the  button  can  be 
released. 
 
 
 
 
 
Checking the hotplate
   
 
Lift  the  lid.  Fit  the  burner  crowns  and  caps 
ensuring  that  they  are  correctly  seated.  Fit 
the pan supports.  
Check  each  of  the  hotplate  burners  in  turn 
by  turning  the  hotplate  tap  to  its  full  on 
position and pressing the ignition button.  As 
soon as the burners are lit the button can be 
released. 
 
Checking lid shut-off device 
 
1.  Lift the lid  
2.  Turn  one  hotplate  tap  to  its  full  on 
position and push the ignition button. 
3.  Close the lid. There should now be no 
gas  supply  to  the  hotplate  and  the 
burner will go out. 
4.  Turn off the hotplate and lift the lid. The 
gas  supply  should  now  be  restored  to 
the hotplate, when the tap is turned on. 
 
Checking the second oven
 
 
1.  Turn  the  second  oven  thermostat 
control  knob  to  Mk.1  and  press  the 
ignition button.  As soon as the burner 
is alight the button can be released. 
2.  When  the  oven  burner  lights  up  there 
should be a low gas rate at first to the 
oven burner which is the F.S.D. bypass 
rate. 
3.  When the F.S.D. phial has heated up it 
opens  the  F.S.D.  valve  and  the  main 
gas stream flows to the burner.