Fitting the stability bracket

 
41 
Carry  out  a  gas  tightness  test  after 
connecting  to  the  gas  supply.    The  gas 
bayonet  connector  must  be  fitted  in  the 
shaded  area  indicated  in  Fig.2.  Take  into 
account  that  it  must  be  possible  to  pull  the 
appliance  forward  sufficiently.  Ensure  the 
hose  does  not  become  trapped  when 
pushing the appliance into position. 
IMPORTANT:  FLEXIBLE  TUBING  USED 
MUST  COMPLY  WITH  BS.669  CURRENT 
EDITION. 
LPG  Flexible  connections  must  be  a  type 
suitable for L.P.G and capable  of operation 
up to 50 mbar and carry a red stripe, band or 
label. 
 
Fitting the stability bracket 
It is recommended that if the appliance is to 
be  installed  with  a  flexible  supply  pipe,  a 
stability  bracket  be  fitted  and  is  available 
from  your  supplier  (see  Important  Safety 
Requirements).    These  instructions  should 
be  read  in  conjunction  with  any  leaflet 
packed with the stability bracket. 
1.  Place  the  appliance  in  its  intended 
position and level appliance. 
2.  Mark off 300mm from the left hand side 
of the appliance as shown in dimension 
'A', Fig 3a.  This is the centre line of the 
fixing bracket. 
3.  Draw a line 100mm from the front edge 
of  the  feet  (see  Fig.3a)  and  remove 
appliance  from  its  position.  Mark  off 
dimension 'B' (see Fig.3a) back from this
 
line on the centre line of the bracket
 to 
locate
  the  front  edge  of  the  lower 
bracket.    Fix  lower  bracket  (with  two 
fixing  holes)  to  the  floor  then  measure 
the height from floor level to engagement 
edge on back of appliance, dimension 'C' 
of Fig. 3b. 
 
4
8
7
m
m
 
(
B
)
 
300mm 
100mm 
20mm 
(A) 
(C) 
Fig.3a. 
Fig.3b. 
2
5
0
 
8
5
0
 
4
5
0
 
7
0
0
 
400 
50  100 
Fig.2.