Cleaning and Maintenance

Cleaning and Maintenance

41

EN

If the door is opened during a fan assisted 
function, the fan stops:
•  This is not a fault. It is a normal operation 

of the appliance, useful when cooking 
foods in order to avoid excessive heat 
escaping. When the door is closed, the 
oven will return to normal operation.

Minimum adjustment

For natural Gas:
Light the burner and turn the knob to the 
minimum position 

. Remove the gas tap 

knob and turn the adjustment screw at the 
side of the tap rod until the desired minimum 
flame is achieved.
Refit the knob and verify that the burner 
flame is stable (when turning the knob 
rapidly from the maximum to the minimum 
position the flame must not go out).
Repeat this operation on the remaining gas 
taps on the cooktop.

For LP Gas:
Turn off the burners and unplug the 
appliance from the electrical power supply.
For regulating the minimum with LP, the 
screws at the side of the tap rod must be 
turned clockwise all the way. Once the 
regulation has been completed, replace the 
seal on the by-passes using paint or similar 
materials. Follow the instructions given in 
point 9 to locate the adjustment screws.

Lubricating the surface burner gas valves

Over time, the surface burner gas valves 
may become stiff or jam. Clean them 
internally and relubricate. This operation 
must be carried out by a qualified 
technician.

If the problem has not been 
resolved or in the case of other 
types of fault, contact your local 
technical support centre.

If other ERRx error messages are 
indicated:
Note down the error message, 
function and set temperature and 
contact your local technical 
support centre.