Installation
41
EN
5 Installation
5.1 Electrical connection
General information
Check the grid characteristics against the
data indicated on the plate. The
identification plate bearing the technical
data, serial number and brand name is
visibly positioned on the appliance. Do not
remove this plate for any reason.
Perform the ground connection using a wire
that is 20 mm longer than the other wires.
The appliance is provided with a five-core
H07RN-F cable (5 x 2.5 mm² referring to
the cross section of the internal conductor).
Connection modes:
• 380-415 V 3N~
5 x 2.5 mm² five-core cable.
Fixed connection
Fit the power line with an omnipolar circuit
breaker in compliance with installation
regulations.
The circuit breaker should be located near
the appliance and in an easily reachable
position.
Connection with plug and socket
To connect:
380-415 V 3N~
with 5 x 2.5 mm² five-core cable.
Check that the plug (not supplied) and
power socket are compatible and of
adequate capacity for the maximum current
draw of the appliance.
The terminal indicated by symbol
links up parts that are normally
earthed. Connect the appliances
appropriately using this terminal in
order to make sure that they are
equipotential.
If the phase voltage drops below
190V~, the performance of the
oven may suffer, not due to the
product itself.
The values indicated above refer
to the cross-section of the internal
conductor.