EN 

1

17

Hood support mounting 

• Lean the hood support 3 against the wall making sure that

holes in the hood support correspond to those in the wall.

• Block the hood support to the wall using 4 12a (5 x 70) screws

supplied with the hood.

• Before fastening the screws definitively make sure that the

support is well-levelled. Only after this  operation proceed with
the definitive tightening of the screws.

3

12a

Air outlet connection in the ducting version  

When installing the hood in ducting version, basing on the in-
staller’s choice, a rigid or a flexible pipe with a ø 150 o 120 mm 
is used in order to connect the hood to the air outlet piping. The 
pipe connection can be made  on the upper part or on the back 
side of the hood. 
AIR OUTLET ON THE BACK SIDE OF THE HOOD 
• When drilling the air outlet hole in the wall proceed in accord-

ance with the scheme in the paragraph concerning the wall
drilling.

• In case the connection is made with a ø 120 mm pipe insert the

reduction flange 9 on the hood body outlet.

• Fix the pipe with an adequate quantity of pipe clamps. This

material is not supplied together with the hood.

• Remove the charcoal filter if present.
AIR OUTLET ON THE UPPER PART OF THE HOOD 
• In case the connection of the hood to the air outlet piping is

made with a ø 150 mm pipe then use a rigid or a flexible pipe.

• In case the connection is made with a ø 120 mm pipe insert the

reduction flange 9 on the hood body outlet.

• Fix the air outlet reduction 8c to the air outlet hole of the hood

support with the screws supplied together with the hood.

• Connect the hood to the piping with a rigid or a flexible pipe.
• Fix the pipe with an adequate quantity of pipe clamps. This

material is not supplied together with the hood.

• Remove the charcoal filter if present.

ø 150

ø 120

9

8c