INSTALLATION

 

Wall drilling and bracket fixing 

When installing the hood in recycling version it has to be taken into consideration that space re-
maining between the hood and the upper limit (ceiling or self) is at least 8-10 cm. 

On the wall, draw: 
• a Vertical line up to the ceiling or upper limit, at the centre of the area in which the hood is

  to be fitted; 

• a Horizontal line at a minimum of 1050 mm above the Cooker Top; .
• As indicated, mark a reference point at 100 mm to the right of the vertical reference line.
• Repeat this operation on the other side, checking that the two marks are level.
• As indicated, mark a reference point at 390 mm above the horizontal reference line, and at

 100 mm to the right of the vertical reference line.

• Repeat this operation on the other side, checking that the two marks are level.
• Drill at the points marked, using a ø 10 mm drill bit.
• Insert the plugs 11 into the holes.

11

12a

100 100

1050

390

1240

175

170

100 100