Installation
42
5 Installation
5.1 Electrical connection
General information
Check the grid characteristics against the
data indicated on the plate. The
identification plate bearing the technical
data, serial number and brand name is
visibly positioned on the appliance. Do not
remove this plate for any reason.
The appliance is equipped with a three-
core H07RN-F cable (3 x 1.5 mm²,
referring to the cross section of the internal
conductor) with plug.
Perform the ground connection using a wire
that is 20 mm longer than the other wires.
Power voltage
Danger of electrocution
• Have the electrical connection
performed by authorised technical
personnel.
• The appliance must be connected to
earth in compliance with electrical
system safety standards.
• Disconnect the mains supply.
• Do not pull the cable to remove the
plug.
• Use H07RN-F cables withstanding a
temperature of at least 75 °C.
• The tightening torque of the screws of
the terminal supply wires must be 1.5 - 2
Nm.
The terminal indicated by symbol
links up parts that are normally
earthed. Connect the appliances
appropriately using this terminal in
order to make sure that they are
equipotential.
If the phase voltage drops below
190V~, the performance of the
oven may suffer, not due to the
product itself.
The values indicated above refer
to the cross-section of the internal
conductor.