Installation

9

EN

U.S. Installation only / 3-wire branch 
circuit

See diagram. Where local codes allow the 
connection of the ground wire from the 
oven to the power supply cable neutral 
wire (white wire):
•  The ground wire must be connected first;
•  If local codes permit, connect the green 

or yellow-green ground wire from the 
appliance and the white wire from the 
appliance to the power supply neutral 
wire (white wire).

•  Connect the red and black leads from 

the appliance to the to the matching 
color wires in the junction box using UL/
CSA listed wire connectors.

U.S. and Canada installation / 4-wire 
branch circuit

•  Separate the green or yellow-green 

wires from the white wires that extend out 
of the end of the appliance cable.

•  The ground wire must be connected first;
•  Connect the green or yellow-green 

ground wire from the appliance to the 
ground wire in the junction box (green 
colored wire) using UL/CSA listed wire 
connectors. Do not connect the 
grounding wire to the neutral wire in the 
junction box.

•  Connect the red and black leads from 

the appliance to the matching color 
wires in the junction box using UL/CSA 
listed wire connectors.

•  Connect the white wire from the 

appliance to the neutral white wire in the 
junction box using a UL/CSA listed wire 
connector.

A

cable from power supply

bw

black wires

B

junction box

gw

white-green or yellow-green wires

C

cable from appliance

rw

red wires

D

UL/CSA listed conduit connector

ww white wires