Installation

39

EN

5 Installation

5.1 Electrical connection

General information

Check the grid characteristics against the 
data indicated on the plate. The 
identification plate bearing the technical 
data, serial number and brand name is 
visibly positioned on the appliance. Do not 
remove this plate for any reason.
The appliance is equipped with a three-
core H07RN-F cable (3 x 1.5 mm², 
referring to the cross section of the internal 
conductor) with plug.
Perform the ground connection using a wire 
that is 20 mm longer than the other wires.

Power voltage
Danger of electrocution

•  Have the electrical connection 

performed by authorised technical 
personnel.

•  The appliance must be connected to 

ground in compliance with electrical 
system safety standards.

•  Disconnect the main power supply.
•  Do not pull the cable to remove the 

plug.

•  Use H07RN-F cables withstanding a 

temperature of at least 75 °C.

•  The tightening torque of the screws of 

the terminal supply wires must be 1.5 - 2 
Nm.

The terminal indicated by symbol 

 links up parts that are normally 

earthed. Connect the appliances 
appropriately using this terminal in 
order to make sure that they are 
equipotential.

If the phase voltage drops below 
190V~, the performance of the 
oven may suffer, not due to the 
product itself.

The values indicated above refer 
to the cross-section of the internal 
conductor.