Instructions for the installer

44

8. OVEN INSTALLATION

The oven must be installed on a free-standing horizontal work top. The distance
from the rear wall must allow easy access to the terminal board for connection
of the power supply cable. Installation must be carried out by a qualified
technician and in compliance with the EEC DIRECTIVES currently in force.

8.1

Electrical connection

Make sure the voltage and the cross-section of the power supply line match the
specifications indicated on the identification plate positioned on the side of the
oven. Do not remove this plate for any reason.

ALFA241
For operation on 380-415V 3N~: use a H07RN-
F type five-core cable (5 x 1.5 mm²).

ALFA341
For operation on 380-415V 3N~: use a H07RN-
F type five-core cable (5 x 4 mm²).

When linking up to the power supply network by plug and socket, the connection
must be completed with a plug of adequate capacity. The plug and wall-
mounted socket must be of the same type (in accordance with CEI regulations).
Make sure that the supply line is suitably earthed. Avoid use of adapters and
shunts.

If the appliance is connected to the power supply network in a permanent
manner, install a multipolar cut-out device on the line, with contact opening
distance equal to or greater than 3 mm located near the appliance and in an
easily reachable position.